Stuffy meeting rooms and bad decisions: the CO2 studies
In 2012, researchers changed one invisible gas in a room and watched decision scores move with it. What they found, and what they were careful to say.

From the notebook · Conference Room B, 3:10 p.m.
Twelve chairs, one whiteboard, and a door that's been shut since lunch. By the third slide the room has that feeling. Nobody says it. Everybody's thinking about the window.
In 2012, a team decided to test the feeling. They put people in an office-like chamber at 600, 1,000 and 2,500 ppm of CO2, and gave them a decision-making test.[1]
The trick: the higher levels came from injecting ultrapure CO2, while ventilation rate and temperature stayed constant.[1] Only the gas changed.
They changed one invisible gas, and the decisions changed with it.
The easy version
- 22 people were tested at 600, 1,000 and 2,500 ppm CO2.[1]
- At 1,000 ppm, six of nine decision-making scales dropped moderately but significantly.[1]
- The authors wrote: "Confirmation of these findings is needed."[1]
The setup
Small, careful and blinded.
Twenty-two participants provided complete data.[1] Each group was exposed to the three conditions in three 2.5-hour sessions, and participants were blinded to the CO2 level.[1]
The finding
Drawn to scale, by how many scales dropped.
- 600 ppm baseline
- 1,000 ppm 6 of 9, moderately
- 2,500 ppm 7 of 9, substantially

The careful part
Good scientists say what they don't know yet.
"Confirmation of these findings is needed," the authors wrote.[1] The bigger 2016 COGfx study pointed the same way.[2] And they flagged why it matters: the effects may limit energy-saving reductions in outdoor air ventilation per person in buildings.[1]
What to do on Monday
CO2 is a fresh-air job.
- Open the door between sessions, and windows when it's safe to do so.[3]
- Run exhaust fans that vent outdoors.[3]
- Put a CO2 monitor in the busiest room. EPA says it's useful for indicating when outdoor air ventilation may be inadequate.[4]
Questions people ask
Did the room just feel warmer?
No. Ventilation rate and temperature were held constant.[1]
Is this one study enough?
No, and the authors said so.[1] It's a strong, careful hint.
Where to next
research, co2-101-your-breath-report-card, office-air-pm25-harvard, clean-air-at-work
Sources
- [1]Satish et al. (2012), Environmental Health Perspectives 120:1671-1677.
- [2]Allen et al.2016), Environmental Health Perspectives 124:805-812 (COGfx
- [3]US EPA, Ventilation and CoronavirusCOVID-19
- [4]US EPA, Reference Guide for Indoor Air Quality in SchoolsAppendix B
Citing an agency or study doesn’t mean it endorses any product. Field names are ours. The science isn’t.