Grandmasters and dust: what 30,000 chess moves reveal about indoor air

  • sample average 8.0%
  • +10 µg/m³ PM2.5 8.0% + 2.1 points

Every chess move is recorded and graded by a computer. So economists put air monitors in tournament halls and counted the mistakes.

TL;DR

Researchers graded about 30,000 moves from official chess tournaments with a chess engine, and 10 µg/m³ more indoor PM2.5 raised a player's probability of an erroneous move by 26.3%. The effect grew with time pressure.

From the notebook · a tournament hall, move 31Read the story

Move 31. Four minutes on the clock. The position is a mess, and somewhere across the board a pawn is about to be very lonely.

Chess is a near-perfect lab: every move is written down, and a chess engine can grade each one. So economists linked air monitors inside official tournament rooms to the moves, and graded the quality of 30,000 moves.[1] The working paper version describes German tournaments in 2017, 2018 and 2019 and 121 players.[2]

Lab notebook: every move recorded / every move graded by an engine / air measured in the venue ✓
Same players, same game, dirtier air, more blunders.

The finding

Drawn to scale. The average error rate in the sample was 8.0%.

The published paper: an increase in indoor PM2.5 of 10 µg/m³ increases a player's probability of making an erroneous move by 26.3%, and time pressure amplifies the damage.[1] The earlier working paper spells out the arithmetic: 2.1 percentage points on a sample average of 8.0% meaningful errors.[2] The chart uses those working paper figures.

Screenshot of the real study page discussed in "Grandmasters and Dust: What 30,000 Chess Moves Reveal About Indoor Air", with pencil rings on the key lines and handwritten notes. Pencil highlights are ours.
One PM2.5 step, two studies
Increase in the chance of a mistake for each 10 micrograms per cubic meter more PM2.5.
Chess playerserroneous move+26.3%per 10 µg/m³ more PM2.5Baseball umpiresincorrect call+2.6%per 10 µg/m³ more PM2.5Each grid is 100 usual mistakes. Coloured dots are the extra ones, rounded to whole dots.That's like...about 26 extra mistakes for every 100 usual ones in chess, and about 3 extra for every 100 calls.

Why it matters off the board

Chess is a job interview for your attention.

Focus, memory and fast decisions under a clock: that's a lot of modern work. It lines up with what researchers found in office workers across six countries and in classrooms that got filters. None of it tells you what any one product will do. It's a good reason to care what's in the room.

The caveats

It's observational: nobody changed the air on purpose. The numbers here come from the working-paper version; the published Management Science version is linked in the sources.

Questions people ask

Were these beginners?

No. The data come from official chess tournaments, plus a replication with games from the top national league.[1]

Does time pressure matter?

Yes. Time pressure amplifies the damage of poor air quality to the players' decisions.[1]

Where to next

Research, 302 office workers, 6 countries, 1 year, When a gas leak put air filters in every classroom, Air and you

Figure sources

  1. Figure 1
    Chance of a meaningful error per move (working paper figures)[2]
  2. Figure 2
    Künn, Palacios & Pestel, IZA working paper. The real paper; the pencil is ours.
  3. Figure 3
    Different people, different mistakes, different air measures: read the two grids as separate findings, not a like-for-like comparison. Both studies are observational. Our math, for scale: percent increases are read as extra mistakes per 100 usual ones. Sources: Künn, Palacios and Pestel 2023, Management Science 69(9):5354, about 30,000 moves, https://doi.org/10.1287/mnsc.2022.4643; Archsmith, Heyes and Saberian 2018, Journal of the Association of Environmental and Resource Economists 5(4), 12-hour PM2.5, https://doi.org/10.1086/698728

Sources

  1. [1]Künn, Palacios & Pestel2023), Indoor Air Quality and Strategic Decision Making, Management Science 69(9):5354-5377 (published abstract
  2. [2]Künn, Palacios & Pestel2019), Indoor Air Quality and Cognitive Performance, IZA Discussion Paper 12632 (working paper; the published version may report different figures

Citing an agency or study doesn’t mean it endorses any product. Field names are ours. The science isn’t.