Reading the fine print on a home air sensor

What is actually inside that little box, why its numbers jump around, and how to read the trend instead of panicking over one digit.

Pencil and wash drawing of a small forest-green home air monitor with a dotted vent grille and a blank screen on a wooden desk. In front of it lies a spec sheet of faint fine print, and a brass magnifying glass resting on the sheet enlarges the fine print into tiny particle dots, one of them rust red, and a small wavy line.

TL;DR

A home air monitor does not weigh anything. Its laser guesses particle mass from scattered light, its true CO2 sensor usually counts on the room airing out about once a week, and its VOC chip can only say that something changed. Read the trend across the day, not one digit, and you will be using it the way it was built.

The monitor on your shelf said one thing at breakfast and something wildly different at lunch. Relax. The gadget is not gaslighting you. It is doing a clever job under very specific assumptions, and once you know them, the wobble stops being scary and starts being useful.

Consider this the owner’s manual the box never came with: three tiny sensors, three honest blind spots, and four rules for reading the display like someone who has seen the wiring.

A monitor is not a reference station

Start with what a monitor is not. The regulatory stations that decide whether a city meets the national air standard are Federal Reference Method or Federal Equivalent Method monitors. For fine particles, the classic reference sampler pulls air through a filter, and the filter is weighed before and after, so the answer is real mass on a real scale.3 EPA lists these reference monitors at about $15,000 to $40,000 each, and air sensors at $100 to $5,000.1

Your monitor has no scale. It has an educated guess. EPA calls air sensors lower in cost, more portable and easier to operate, and says their accuracy, lifetime and reliability vary with the technology, the components and the conditions.1 That is not a flaw hiding in the fine print. It is the fine print.

EPA adds two more reality checks. There are currently no widely accepted indoor concentration limits for most pollutants, so the color on your display was picked by the manufacturer. And the price of a monitor does not necessarily indicate how well it will perform.2 The colors are a mood. The trend is the data.

The laser-flashlight trick

The particle sensor in most home monitors is a tiny optical chamber. A small light source shines across the air stream, particles drifting through the beam scatter some of it, and a detector turns the flashes into a number. EPA puts it plainly: the light scattered by particles is used to estimate particle mass, and the amount of scatter can vary with the size, shape and chemical composition of the particles.1

Read that again. The sensor never weighs anything. It sees brightness, then converts brightness to mass using assumptions about what the particles are like. When your particles match, it does great. When they don’t, it is guessing about a guess.

How great is great? In a Berkeley Lab test, seven consumer monitors faced candles, cigarettes, incense, cooking, dust and an ultrasonic humidifier in a 4,200 cubic foot lab (120 cubic meters). Four of them stayed time-matched and within 50% to 200% of the estimated true mass for most sources, right alongside two research monitors.4 Two others responded to most sources but reported well under 50% of the estimated true mass.4 Plenty good for spotting events. Not a lab in a box.

Inside the little box: 3 sensors, 3 blind spots

Drawing is illustrative.

What it measures

Optical PM2.5 laserScattered light, then amass guess.True NDIR CO2 (not eCO2)Infrared absorbed by CO2gas, measured directly.Metal-oxide VOC chipA heated surface that reactsto many gases.

Its number one blind spot

Humid air reads too highAnd particles under 0.3 µmslip past it.Needs fresh air weeklyIt resets its 400 ppmbaseline from the lowest reading.Cannot name the gasIt only says that somethingchanged.

Two ways the laser gets fooled

Fooled by water. Many low-cost particle sensors have no heater or dryer at the inlet, so water riding on a particle gets counted as particle.6 Researchers tested a Plantower PMS1003, a common low-cost particle sensor, in the lab and outdoors and found significant increases in particle readings once relative humidity climbed above about 75%. In fog, that sensor’s PM10 reading ran 46% above a standard monitor that dries the air first.6

The pattern shows up at national scale too. EPA researchers compared almost 12,000 daily PurpleAir PM2.5 averages with reference monitors across 16 states. The raw sensor data overestimated PM2.5 by about 40% in most parts of the US, and the overestimate grew as humidity rose between 30% and 80%.5 EPA’s final correction, which includes a humidity term, cut the typical error in the raw data from 8 to 3 micrograms per cubic meter.5

Steam is the same water story in spirit. Nobody tested your bathroom for this guide, so take this as our practical suggestion rather than a study result: keep the monitor out of the path of shower and kettle steam.

Ultrasonic humidifier mist is messier. In the Berkeley Lab test, the mist from an unfiltered ultrasonic humidifier was measured quantitatively by the research monitors and by three of the consumer monitors, while two other consumer monitors reported only 14% to 24%, and under 5%, of the estimated true mass.4

Fooled by size. Very small particles scatter very little light. In that same test, all seven consumer monitors and both research monitors substantially under-reported or missed events where the mass was in particles smaller than 0.3 micrometers.4 A separate Berkeley Lab test of six monitors under $300 found low or no response to sources made entirely of particles smaller than 0.25 micrometers, including steady candle flames and cooking without frying or grilling.7 EPA’s general rule fits both findings: this optical method can detect only a narrow range of particle sizes.1

So a calm reading does not always mean calm air. A quiet monitor next to a steady candle flame is a monitor doing exactly what it was built to do.

What fools the laser, and what it misses

Test numbers are listed under Figure sources.

Reads too high

Humid airAbove about 75% RH, readingsrose sharply (lab and field).FogPM10 read 46% above amonitor that dries the air.Raw US field dataAbout 40% too high, and thegap grew from 30% to 80% RH.

Reads too low, or misses it

Particles under 0.3 µmAll 9 monitors in one testmissed or under-reported them.Steady flames, gentle cookingLow or no response in asix-monitor test.Humidifier mist: a split voteSome monitors read it well,others reported 24% or less.

CO2: the real one and the lookalike

The CO2 sensor in a good monitor is NDIR, short for non-dispersive infrared. Infrared light crosses a small chamber, CO2 molecules absorb a specific wavelength of it, and the sensor works out the CO2 level from how much light goes missing.8 That is a direct measurement of the gas itself, which makes it the most trustworthy sensor in the bundle. In one chamber study, most tested devices reported CO2 within 15% of the reference.9

NDIR sensors have one quiet habit, though. Their zero point drifts, so many use Automatic Baseline Correction, or ABC. The sensor tracks its own lowest reading over about a week and assumes that low point is fresh outdoor air, around 400 ppm.1011 That only works if the room actually reaches fresh-air levels at least once in each 7-day cycle.11 One manufacturer note is blunt about the downside: if the sensor never reads normal 400 ppm air, over time it will display inaccurate CO2 levels.12

So airing the room out now and then also keeps an ABC monitor honest. A tight room occupied around the clock is exactly where that baseline can slip.

Now meet the lookalike. Some cheaper devices show a number labeled eCO2, or equivalent CO2. It is not a CO2 measurement. In a study of low-cost multimodal monitors, the authors described eCO2 as an estimate derived from a total VOC measurement, and found a poor correlation with reference CO2, 0.38 or lower, even though the readings mostly rose and fell at the same moments.13

That last part is why eCO2 is so convincing. People breathe out VOCs too, so the line wiggles when guests arrive. But cooking and cleaning move a VOC chip just as easily, with no extra breathers in the room.14 Check the spec page for the letters NDIR. If all you find is eCO2 or equivalent CO2, you have the lookalike.

TVOC: one number, many suspects

The total VOC reading usually comes from a metal-oxide chip: a heated surface whose electrical resistance shifts when gases land on it.15 EPA says most tVOC sensors are metal-oxide or photoionization types, that they detect a wide variety of VOCs but not all of them, and that they respond more to some compounds than others.1

“the reported concentration cannot be attributed to a specific compound or even the sum of several compounds.”

US EPA, Enhanced Air Sensor Guidebook1

In plain English, the chip knows something touched it, not what. Sensirion, which makes a widely used family of these chips, says its VOC Index responds to odourless VOCs too, but cannot discriminate between them.14

That is why many monitors now show an index instead of a concentration. Sensirion explains that a true concentration cannot be properly provided under field conditions, so its VOC Index is relative to the sensor’s recent history: 100 means the average indoor gas composition over the past 24 hours, higher means more VOCs than that baseline, lower means fewer, on a scale from 1 to 500.1415

So a room that has been smelly all day sits at 100, just like a spotless one. The index measures change, not safety, and EPA’s own advice for tVOC sensors is to hunt for spikes near a source.{S(1)}

The four-rule pro guide

Rule 1: read patterns and spikes, not decimals. EPA suggests comparing readings before, during and after an activity like cooking.2 How high the line climbed, how fast, and how long it took to come back tell you far more than any single digit.

Rule 2: know which sensor is inside. Look for NDIR on the CO2 line, an optical laser on the PM2.5 line, and read TVOC as a something-changed flag. If the box doesn’t say, assume the cheaper kind.

Rule 3: respect placement and calibration. EPA suggests the breathing zone, about 3 to 6 feet up for a typical adult, with airflow into the monitor not blocked by a wall. Keep it away from stoves, stored cleaning products and drafts from vents or open windows.2 Our additions: skip the steam and humidifier mist, don’t breathe straight onto the vent, and air the room out now and then. EPA also says particle sensors often last about 1 to 4 years as particles build up inside, so an old, dusty monitor deserves a little less trust.1

Rule 4: cross-check with the outdoors and the room. AirNow.gov calls itself a one-stop source for air quality data, starting with your local area.16 If the outdoor numbers are up and your PM2.5 climbs after you open a window, you have an easy story. If the monitor spikes just as someone starts a shower, the shower is your suspect. Context beats the number.

A home monitor is a trend reader, not a judge. Let it show you the shape of your day. The wobble was never the problem. The panic was.

Keep reading

Figure sources

  1. Hero drawing. Drawing is illustrative. It shows a small generic home air monitor with a vent grille and a blank screen beside a spec sheet of illegible fine print, with a brass magnifying glass that enlarges the fine print into tiny particle dots and a small wavy line. No real device is depicted.
  2. Inside the little box. Drawing is illustrative. It summarizes source 1 (PM sensors estimate mass from scattered light and detect a narrow size range; tVOC sensors are mostly metal-oxide or photoionization types whose readings cannot be attributed to a specific compound), source 8 (NDIR sensors measure CO2 by infrared absorption), source 13 (eCO2 is an estimate derived from a total VOC measurement), sources 14 and 15 (metal-oxide chip signal follows sensor resistance on a heated surface; VOC Index is relative), sources 4 and 6 (humidity over-reading; particles under 0.3 micrometers missed), and sources 10 to 12 (ABC assumes the lowest reading in about a week is fresh air near 400 ppm). The row labels are our plain-language summaries, not quoted findings.
  3. What fools the laser. Jayaratne et al. 2018 (source 6): a Plantower PMS1003 showed significant increases in particle number and mass readings at relative humidity above about 75%, in the lab and the field; during fog its PM10 reading was 46% greater than a standard monitor with a charcoal dryer at the inlet. Barkjohn et al. 2021 (source 5): almost 12,000 24-hour averages from collocated PurpleAir sensors and FRM or FEM monitors in 16 states; raw PurpleAir data overestimated PM2.5 by about 40% in most parts of the US, with overestimation increasing between 30% and 80% relative humidity; the final correction cut RMSE from 8 to 3 micrograms per cubic meter. Singer and Delp 2018 (source 4): all 7 consumer and both research monitors substantially under-reported or missed events where emitted mass was in particles smaller than 0.3 micrometers; mist from an unfiltered ultrasonic humidifier was measured quantitatively by the research monitors and three consumer monitors, while two other consumer monitors reported 14% to 24% and under 5% of the estimated true mass. Wang, Delp and Singer 2020 (source 7): six monitors each priced under US$300 showed low or no response to sources made entirely of particles smaller than 0.25 micrometers, including steady candle flames and cooking without frying or grilling (shown as “gentle cooking”). The 4,200 cubic foot lab size is our conversion of 120 cubic meters.

Method notes

  • This is an explainer about how low-cost sensors work. Practical suggestions (keeping a monitor out of shower steam and humidifier mist, not breathing onto the vent, airing a room out for the CO2 baseline, assuming the cheaper sensor when a spec sheet does not say) are our suggestions, not findings from the sources.
  • The studies cited tested specific low-cost sensors and monitors, not Jaspr, and not every monitor on the market. Results depend on the device, the source and the room. Sensirion, Senseair, ScioSense and CO2Meter are sensor makers or sellers, cited only to explain how their algorithms work.
  • Citing a study or government agency never implies endorsement of any product, including Jaspr. Nothing in the Field Guide is medical advice. Jaspr is an air scrubber, not a medical device.

Sources

  1. US EPA Office of Research and Development. The Enhanced Air Sensor Guidebook (EPA/600/R-22/213), September 2022. Chapter 2, Table 2-3, and “How Do Air Sensors Work?” Opened Nov 24, 2026. www.epa.gov/air-sensor-toolbox/how-use-air-sensors-air-sensor-guidebook
  2. US EPA. Low-Cost Air Pollution Monitors and Indoor Air Quality. Opened Nov 24, 2026. www.epa.gov/indoor-air-quality-iaq/low-cost-air-pollution-monitors-and-indoor-air-quality
  3. US Code of Federal Regulations. 40 CFR Part 50, Appendix L, Reference Method for the Determination of Fine Particulate Matter as PM2.5 in the Atmosphere (sections 2.1 and 2.2). Opened Nov 24, 2026. www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-50/appendix-Appendix%20L%20to%20Part%2050
  4. Singer BC, Delp WW. Response of consumer and research grade indoor air quality monitors to residential sources of fine particles. Indoor Air 2018;28(4):624-639. doi.org/10.1111/ina.12463
  5. Barkjohn KK, Gantt B, Clements AL. Development and application of a United States-wide correction for PM2.5 data collected with the PurpleAir sensor. Atmospheric Measurement Techniques 2021;14:4617-4637. doi.org/10.5194/amt-14-4617-2021
  6. Jayaratne R, Liu X, Thai P, Dunbabin M, Morawska L. The influence of humidity on the performance of a low-cost air particle mass sensor and the effect of atmospheric fog. Atmospheric Measurement Techniques 2018;11:4883-4890. doi.org/10.5194/amt-11-4883-2018
  7. Wang Y, Delp WW, Singer BC. Performance of low-cost indoor air quality monitors for PM2.5 and PM10 from residential sources. Building and Environment 2020;171:106654. doi.org/10.1016/j.buildenv.2020.106654
  8. British Standards Institution. PAS 4023:2023, Selection, deployment and quality control of low-cost air quality sensor systems in outdoor ambient air, Code of practice, Annex D.1.4 (non-dispersive infrared sensors). Opened Nov 23, 2026. www.bsigroup.com/siteassets/pdf/en/insights-and-media/insights/brochures/pas-4023.pdf
  9. Demanega I, Mujan I, Singer BC, Anđelković AS, Babich F, Licina D. Performance assessment of low-cost environmental monitors and single sensors under variable indoor air quality and thermal conditions. Building and Environment 2021;187:107415. doi.org/10.1016/j.buildenv.2020.107415
  10. Senseair. The Senseair ABC Algorithm. Opened Nov 24, 2026. senseair.com/the-senseair-abc-algorithm/
  11. ScioSense. ENS190 NDIR CO2 Sensor datasheet, version 1.2, February 2026, sections 6.3.1 and 7.3.3. Opened Nov 24, 2026. www.sciosense.com/wp-content/uploads/2026/03/ENS190-Datasheet.pdf
  12. CO2Meter. AN131, CO2 Sensor Calibration: What You Need to Know (ABC Calibration section). Opened Nov 24, 2026. www.co2meters.com/Documentation/AppNotes/AN131-Calibration.pdf
  13. Coulby G, Clear A, Jones O, Godfrey A. Low-cost, multimodal environmental monitoring based on the Internet of Things. Building and Environment 2021;203:108014. doi.org/10.1016/j.buildenv.2021.108014
  14. Sensirion. What is Sensirion’s VOC Index? (information note). Opened Nov 24, 2026. sensirion.com/media/documents/02232963/6294E043/Info_Note_VOC_Index.pdf
  15. Sensirion. SGP40 Data Sheet, sections 3.1 and 3.2 (raw signal proportional to the logarithm of sensor resistance; VOC Index scale 1 to 500, 100 is the average over the past 24 hours). Opened Nov 24, 2026. sensirion.com/media/documents/296373BB/6203C5DF/Sensirion_Gas_Sensors_Datasheet_SGP40.pdf
  16. AirNow.gov. AirNow home page. Opened Nov 24, 2026. www.airnow.gov/
Field names are ours. The science isn’t.Citing an agency or study doesn’t mean it endorses this guide, Jaspr, or any product.